IR-BA Series High-speed Compact Radiation Thermometers
The IR-BA series is a non-contact and high-speed compact radiation thermometer. The card sized thermometer with built-in signal converting function of 4-20mA output can easily be installed in narrow places, production lines and small equipment.
A standard speed type and a high-speed type (50ms/95%) are respectively available in standard type and small-target/short-distance type and small-target/long-distance type, and special application types for glass, lamp-anneal, film, and burning gas.
Peripheral units including:
Indicator with power supply, converter with reflection correction, etc.
CE
Excluding special application types (IR-BAX)
General Type
IR-BAT1A
Standard
0-300°C
100ms
Φ40/500mm
Less than 300°C:
±3°C
300°C or higher:
±1% of measured value
(at ε = 1.0 and reference operating condition)
8 to 14µm
IR-BAT1B
0-600°C
IR-BAT2A
Small target/
Short distance
0-300°C
Φ5/80mm
IR-BATSA
Small target/
0-300°C
Φ40/1000mm
IR-BATSB
Long distance
0-600°C
High-Speed Type
IR-BAT1M
Standard
0-300°C
50ms
Φ40/500mm
Less than 300°C:
±3°C
300°C or higher:
±1% of measured value
(at ε = 1.0 and reference operating condition)
8 to 14µm
IR-BAT1P
0-600°C
IR-BAT2M
Small target/
Short distance
0-300°C
Φ5/80mm
IR-BATSM
Small target/
Long distance
0-300°C
Φ40/1000mm
IR-BATSP
0-600°C
Application Type
IR-BAXG1
Glass
100-400°C
1s
Φ20/150mm
±4°C
4.6 to 5.2µm
IR-BAXL1
Lamp anneal
400-1300°C
1s
Φ40/500mm
1%
3.43µm half-band width 120nm
IR-BAXF1
Polyethylene
80-250°C
1s
Φ40/500mm
±4°C
IR-BAXF2
Polyester
50-150°C
1s
Φ40/500mm
±4°C
7.6 to 8.4µm
IR-BAXH1
Burning gas
500-1300°C
10s
Φ100/1000mm
1.5%
4.3µm
Measurement
Wide-band system (General type and high-speed type)
Narrow-band system (Special application type)
Element
Thermopile
Resolution
0.2°C (0-300°C) general type
0.5°C (0-600°C) high-speed type
Repeatability
±0.2°C (0-300°C) general type
±0.3°C (0-600°C) high-speed type
Optics
Ge lens
Emissivity
1.99 to 0.10 by digital switch
Analog output
4 to 20mADC (Load: less than 280Ω)
Working temperature
0 to 50°C
Power
12 to 24VDC
Current consumption
60mA or lower
Connecting cable
Standard 2m 5m for IR-BAXH1
Casing
Diecast aluminum
Water proofing
JIS C-920 Drip-proof II, IP-X2
Mounting
Fixing 2 x M4 screws or tripod
Weight
About 220g
CE
EN61326 Class A, EN61326 Annex A
Except special application types and extension cable type
Conditions for CE conformance
1. An individual DC power unit for thermometer is required.(Recommended power unit: IR-ZFEP)
2. All of the thermometer, the connection cable, and a DC power unit should be used indoors.