CHINO
Infrared Thermometers
Discontinued
IR-CA Series High-speed Compact Infrared Thermometers
The IR-CA series is a non-contact and high-speed (3ms) compact radiation thermometer covering medium and high temperature range by using the detecting element of InGaAs or Si. The thermometer with converting function has a digital display of temperature, parameter setting keys, and a direct viewfinder. The thermometer can be placed at any place due to a large distance factor. IR-CA Series
TabView Example - Basic From Existing Markup
    Functional digital display of temperature and parameter setting keys.
    Free installation by a direct viewfinder and a long distance factor.
    High-speed response of 3ms.
    Wide range
    High accurate type with a short spectral response.
    No moving part like as chopper guarantees long reliability.
    Various accessories for every kinds of installation atmosphere.
    Model Type
    IR-CAI For medium temperature
    IR-CAS For high temperature
    IR-CAQ High functional type
    IR-CAB Low temperature/long spectral response
    IR-CAE Low short/short spectral response
    IR-CAP For low/medium temperature
    IR-CAW Ultra-wide type
    IR-CAN For polyester film
    IR-CAM For polyethylene film
    IR-CAR For furnace inside
    IR-CAG For glass
    IR-CAT For silicone
    IR-CAU For gallium arsenide
    Model Low temp/
    long wavelength type
    IR-CAB
    Low temp/
    short wavelength type
    IR-CAE
    For low/
    medium temp
    IR-CAP
    Ultra-wide type
    IR-CAW
    Measuring system Wide-band radiation thermometer Narrow-band radiation thermometer Wide-band/narrow-band radiation thermometer
    Element Pyroelectric PbSe PbS TP/InGaAs/Si
    Spectral response 8 - 13µm 4µm 2µm 8 - 13/1.55/0.9µm
    Measuring range -50 - 100°C 20 - 1000°C 30 - 200°C 100 - 500°C 80 - 250°C
    150 - 450°C
    200 - 800°C
    200 - 3000°C
    Accuracy rating *1 ±0.8°C Less than 200°C … ±2°C
    200°C or higher … ±1% of measured value
    ±2°C ±3°C Less than 500°C … ±3°C
    500°C or higher … ±5°C
    Less than 1000°C … ±5°C
    1000°C to lower than 1500°C…±0.5% of measured value
    1500°C to lower than 2000°C…±1% of measured value
    2000°C or higher … ±2% of measured value
    Repeatability Within 0.2°C Within 1°C Within 0.5°C Within 1°C Within 1°C
    Temperature drift: Less than 100°C ---- 0.05°C/°C
    100°C to less than 700°C ---- 0.05% of measured value/°C
    700°C or more ---- 0.025% of measured value/°C
    0.15°C/°C Less than 500°C … ±0.15°C/°C
    500°C or higher … ±0.25°C/°C
    Less than 1000°C … ±0.2°C/°C
    1000°C or higher … ±0.02% of measured value/°C
    Resolution 0.1°C 1°C 0.1°C 1°C
    Response time 2s 0.2s 0.02s 0.1s
    Optics Fixed focus type Focusable type Fixed focus type
    Measuring diameter Φ37/1000mm
    Φ20/1000mm
    Φ10/500mm
    Φ15/400mm
    Φ10/500mm
    Φ8/200mm
    Φ4/200mm
    Φ40/2000mm
    Φ2/100mm
    Φ37/1000mm
    Φ15/400mm
    Φ8/200mm
    Measuring
    distance/
    distance
    factor
    Distance factor:200
    Measuring
    distance/
    distance factor
    Distance factor: 50, 200, 300
    Φ29/1000mm
    Sighting Laser spot, without direct viewfinder Direct viewfinder
    Lens aperture Φ15mm Φ20mm Φ30mm
    Power consumption Maximum 5VA Maximum 10VA Maximum 3VA
    *1: At ε1.0 and reference operation condition
    Reference condition: 23 ± 5°C, 35 to 75%RH
    Model For polyester film
    IR-CAN
    For polyethylene film
    IR-CAM
    For furnace inside
    IR-CAR
    For glass
    IR-CAG
    For silicone
    IR-CAT
    For gallium arsenide
    IR-CAU
    Measuring system Narrow-band radiation thermometer
    Element Pyroelectric PbSe MCT Si
    Spectral response 8µm 3.43µm 3.8µm 5µm 0.6 - 0.96µm 0.6 - 0.9µm
    Measuring range 0 - 300°C 30 - 300°C 350 - 1100°C
    450 - 1300°C
    500 - 1500°C
    100 - 800°C
    200 - 1800°C
    400 - 2800°C
    400 - 800°C
    500 - 1000°C
    600 - 1200°C
    400 - 800°C
    500 - 1000°C
    Accuracy rating *1 Less than 200°C … ±2°C
    200°C or higher … ±1% of measured value
    Less than 1000°C … ±5°C
    1000°C or higher … ±0.5% of measured value
    Less than 1000°C … ±5°C
    1000°C to lower than 1500°C…±0.5% of measured value
    1500°C to lower than 2000°C…±1% of measured value
    2000°C or higher … ±2% of measured value
    Less than 600°C … ±3°C
    600°C or higher … ±0.5% of measured value
    Repeatability Within 1°C Within 0.5°C
    Temperature drift: 0.15°C/°C Less than 1000°C … ±0.2°C/°C
    1000°C or higher … ±0.02% of measured value/°C
    Less than 700°C … ±0.1°C/°C
    700°C or higher … ±0.015% of measured value/°C
    Resolution 1°C 0.5°C
    Response time 1s 0.02s 0.1s 0.04s
    Optics Fixed focus type Focusable type
    Measuring diameter Φ37/1000mm
    Φ15/400mm
    Φ8/200mm
    Measuring distance/distance factor
    Distance factor: 100, 200
    Measuring distance/distance factor
    Distance factor: 50, 100, 200
    Measuring distance/distance factor
    Distance factor: 100, 200
    Sighting Laser spot, without direct viewfinder Direct viewfinder
    Lens aperture Φ15mm Φ20mm
    Power consumption Maximum 5VA Maximum 10VA
    Common Specifications
    Emissivity compensation Emissivity setting range … 1.9999 to 0.050
    Signal modulation DELAY, PEAK
    Display Temperature, parameters, 4 digits
    Analog output 4 to 20mADC, Isolate output
    Math function Zero/span adjustment, automatic emissivity computation, output correction
    Self-diagnosis Abnormal instrument temperature, parameter error
    Working temperature 0 to 50°C
    Power supply 24VDC (Allowable voltage fluctuation range … 22 to 28VDC)
    Connection Connector or terminal connection
    Case material Aluminum
    Weight About 1.3kg
    CE EN61326 + A1 Emission Class A Immunity Annex A (complying with connector connection only)
    Options
    Communications interface *2 RS-485, transmission of measured data, transmission and receiving of parameters
    Analog input *2 Input signal … 4 to 20mADC, selection of emissivity remote settings or automatic emissivity computation
    Contact input *2 1 point, peak-hold reset or sample hold, dry contacts or open collector
    Contact output *2 1 point, high (low) alarm or error signal, photo-coupler 30VDC max 50mA
    Laser sighting Semi conductor laser built-in, Laser: less than 1mW (645nm), class 2
    Without direct viewfinder
    *2: 1 only is to be selected from the options marked with *2.
    PS Sheet IR-CA Series PSE-469A Download
© 2024 CHINO Works America Inc.