HN-CQ𝟘 |
HN-CFA |
HN-CGA |
HN-CV𝟘 |
HN-CP𝟘 |
High Polymer capacitance type |
0 to 100%RH (no dew condensation) |
±2%RH (at 0 to 90%RH and 25°C), ±3%RH (at 90 to 95%RH and 25°C) |
±0.1%RH/°C (at the range of 5 to 80°C) |
Within 15 seconds (at 90% response, 25°C and under 0.1m/s wind flow) |
Within 1 minute (at the same condition shown left) |
4 to 20mADC, 2-wire transmission (against 0 to 100%RH) |
500Ω or lower (at 24VDC power supply) |
Platinum resistance thermometer Pt100 JIS class A |
0 to 50°C |
-40 to 80°C |
-40 to 180°C |
0 to 50°C |
0 to 80°C |
±0.3°C |
±0.5°C |
±0.3°C |
4 to 20mADC, 2-wire transmission (against measuring range) for HN-C𝟘A
Pt100, 3-wire system for HN-C𝟘B |
500Ω or lower (at 24VDC power supply) |
Plug-in interchangeable |
Plug-in interchangeable (including cable) |
Plug-in interchangeable |
0 to 50°C |
|
|
|
|
0 to 50°C |
-40 to 80°C |
-40 to 180°C |
0 to 50°C |
0 to 80°C |
12 to 24VDC ± 1V |
|
Crump type no-screw terminal connection |
Terminal connection (M4 x 5) |
Resin |
Die-cast aluminum |
---- |
Resin |
SUS |
Screw fixing (M4 x 2) or DIN rail mounting |
Screw (M4 x 2) |
Flange (JIS 5K 25A) |
About 160g |
About 220g |
About 240g |
About 1.6kg |
Fixtures for wall-mounting |
---- |
---- |
---- |
Cable length: 1m, 2m, 3m (to be specified) |
---- |
---- |